Skip to content

Free shipping on orders over $99.

8:30 to 5 ET(704) 555-0142
Not sure what you have? Send the part number(704) 555-0142
Edwards Edwards 3-IDC8/4 The 3IDC 84 Supports Supervised Circuits for N.O. Contacts with Latching or Nonlatching Operati
Edwards Edwards 3-IDC8/4 The 3IDC 84 Supports Supervised Circuits for N.O. Contacts with Latching or Nonlatching OperatiEdwards Edwards 3-IDC8/4 The 3IDC 84 Supports Supervised Circuits for N.O. Contacts with Latching or Nonlatching OperatiEdwards Edwards 3-IDC8/4 The 3IDC 84 Supports Supervised Circuits for N.O. Contacts with Latching or Nonlatching OperatiEdwards Edwards 3-IDC8/4 The 3IDC 84 Supports Supervised Circuits for N.O. Contacts with Latching or Nonlatching OperatiEdwards Edwards 3-IDC8/4 The 3IDC 84 Supports Supervised Circuits for N.O. Contacts with Latching or Nonlatching OperatiEdwards Edwards 3-IDC8/4 The 3IDC 84 Supports Supervised Circuits for N.O. Contacts with Latching or Nonlatching Operati

Edwards 3-IDC8/4 The 3IDC 84 Supports Supervised Circuits for N.O. Contacts with Latching or Nonlatching Operations, Ideal for Monitoring and Control

Edwards
$91.67
In stock — 14 available
In stock · ready to ship
Ships today — order before 3:00 PM ET
Delivery in 3–5 business days
Ships from the USA — free shipping over $99
BrandEdwards
SKU3-IDC8/4
TypeModules
Variants1

The 3-IDC 8/4 is ideal for retrofit projects where existing wiring, smoke detectors and signals may not need replacing

Flexibility built right into the IDC module allows connection of normally open contact devices, and traditional 2 wire smoke detectors.

The 3-IDC 8/4 configures for use with N.O. contacts and supports supervised Supervisory and Monitor circuits with latching or non-latching operations.

Use the monitor operation with the non-latching function and the circuit serves as a supervised event follower, efficiently covering critical fan and damper operations. Circuits will annunciate on the 3-LCD, control display modules or at any other display device on the network.

Up to 30 photoelectric or 50 ionization smoke detectors are supported per circuit. All circuits may be programmed for non-verified or verified smoke operation.

The 3-IDC 8/4 incorporates software selectable impedance ranges for Input Circuit configurations, eliminating conventional smoke detector compatibility problems.

Ranges include open circuit, shorted condition and high and low impedance (relative to the main impedance setting), allowing the use of various detectors of similar impedance and European alarm circuit operation.

Documents

FAQ

How many circuits does the 3-IDC8/4 have?
Eight supervised Class B hardwired circuits. All eight can be inputs, or up to four of the eight can be configured as notification appliance circuits.

What devices can be connected?
Normally open contact devices and traditional 2-wire smoke detectors, which makes it suited to retrofit projects that keep existing wiring and detectors.

How are the inputs configured?
Each circuit can be latching or non-latching, and verified or non-verified. The NACs support regulated and special application appliances.

Questions about this product

Is Edwards 3-IDC8/4 The 3IDC 84 Supports Supervised Circuits for N.O. Contacts with Latching or Nonlatching Operations, Ideal for Monitoring and Control in stock?

Yes — 14 units are available and ready to ship from our US warehouse.

How fast will Edwards 3-IDC8/4 The 3IDC 84 Supports Supervised Circuits for N.O. Contacts with Latching or Nonlatching Operations, Ideal for Monitoring and Control ship?

Orders placed before 3:00 PM ET ship the same business day. Delivery takes 3–5 business days inside the USA.

Where does Edwards 3-IDC8/4 The 3IDC 84 Supports Supervised Circuits for N.O. Contacts with Latching or Nonlatching Operations, Ideal for Monitoring and Control ship from?

It ships from the United States. Standard delivery is 3–5 business days, and orders placed before 3:00 PM ET go out the same day.

Cart0
Your cart is empty

Have an account? Log in to check out faster.

Continue shopping