Notifier MODBUS-GW — embedded gateway linking a Modbus/TCP network to fire alarm control panels on a NOTI-FIRE-NET network.

It reaches the fire network through the network port on any NCM and presents panel data to a Modbus master over Ethernet. No configuration utility is needed: enter the TCP/IP settings and the nodes to monitor, and it auto-discovers and reports the mapping. UL recognises it as an ancillary reporting device.

  • Monitors four compatible NFN or high-speed NFN nodes, not counting its own
  • Reports event type, active, enabled and acknowledged state, device type, analog value from 4 to 20 mA modules, troubles
  • Reads up to 100 registers at a time, analog values 10 registers
  • One Modbus master, one-byte Unit IDs, Modbus Spec. V1.1b
  • Panels: NFS-320, NFS-640, NFS2-640, NFS-3030, NFS2-3030
  • UL 864 Ninth Edition and UL 2017; UL/ULC file S635
  • Static IP, 100Base-T, TCP port 502

It also needs an NCM or HS-NCM board and NFN network 5.0 or above, and the CAB-4 cabinet and CHS-4L chassis are sold separately. Notifier states the CLSS Gateway Modbus feature may reside on the same system as this one; what decides between them is that this gateway reads 4 to 20 mA analog values and the CLSS feature does not.

Documents

FAQ

How many NFN nodes can the MODBUS-GW monitor?
Four compatible NFN or high-speed NFN nodes, not including itself.

How many Modbus masters are supported?
One standard Modbus/TCP master.

What network settings does it need?
A static IP address and TCP port 502.

How is it configured?
No separate configuration utility is needed: enter the TCP/IP settings and the nodes to monitor, and the gateway auto-discovers the points and supplies a CSV report of the mapping.

Questions about this product

Is Notifier MODBUS-GW Modbus/TCP Gateway for NOTI-FIRE-NET Fire Alarm Networks in stock?

Yes — 19 units are available and ready to ship from our US warehouse.

How fast will Notifier MODBUS-GW Modbus/TCP Gateway for NOTI-FIRE-NET Fire Alarm Networks ship?

Orders placed before 3:00 PM ET ship the same business day. Delivery takes 3–5 business days inside the USA.

Where does Notifier MODBUS-GW Modbus/TCP Gateway for NOTI-FIRE-NET Fire Alarm Networks ship from?

It ships from the United States. Standard delivery is 3–5 business days, and orders placed before 3:00 PM ET go out the same day.

Cart0
Your cart is empty

Have an account? Log in to check out faster.

Continue shopping