Potter EVD-1C Electronic Vibration Detector
| Brand | Potter |
|---|---|
| SKU | EVD-1C |
| Type | Sensors |
| Variants | 1 |
Potter EVD-1C — EVD-1 Safe Pak: the EVD-1 electronic vibration detector supplied with an HSC high security safe contact, for safe and vault protection.
The EVD-1 uses piezo sensor technology and signal processing to detect short, large-amplitude attacks such as explosions, hammering or chiseling, and long, small-amplitude attacks such as torches, thermic lances, drills, grinders or cutting discs. It is UL certified for primary protection of mercantile or bank premises, safes, vaults and ATMs, and for supplementary protection of file cabinets, display cases, walls and ceilings. It must be used with an appropriate UL certified control unit.
Specifications
| Model | EVD-1C Safe Pak (EVD-1 detector + HSC safe contact) |
| Power input | 9.0 to 16.0 VDC, 12 VDC nominal; 0.1 V max ripple |
| Current at 12 VDC | 26 mA standby, 24 mA alarm, 34 mA tamper |
| Alarm relay | Form C, 2.0 A at 30 VDC |
| Tamper contact | Form A, 2.0 A at 30 VDC |
| Dimensions | 5.10 x 3.26 x 1.20 in. (H x W x D) |
| Enclosure | Die-cast aluminum base, 22 gauge stamped steel cover |
| Weight | 0.64 lb (EVD-1) |
| Certifications | UL and ULC |
Features
- Integral multi-color status LED
- Built-in test circuit with remote test and annunciator capability
- Supervised microprocessor and independent tamper output
- On-board test point and built-in accumulator
Installation notes
- The RTA remote test annunciator and high security "B" cable are optional equipment required for a UL complete safe installation
- If powered from a burglar panel with ground fault detection, a separate UL certified 12 VDC supply may be needed, or the safe insulated from ground
- For applications needing more than one detector, the EVD-2 system may be more suitable
Documents
FAQ
What is included in the EVD-1C?
The EVD-1C Safe Pak includes the EVD-1 detector and an HSC high security safe contact.
What power does it need?
9.0 to 16.0 VDC, 12 VDC nominal, drawing 26 mA in standby. A separate UL certified 12 VDC supply may be needed if the burglar panel has ground fault detection.
What else is needed for a UL complete safe installation?
The RTA remote test annunciator and the high security "B" cable are optional items required for a UL complete safe installation.
Can one EVD-1 protect several safes?
The EVD-1 is a stand-alone detector. Potter suggests the EVD-2 system where more than one detector is needed.
Questions about this product
Is Potter EVD-1C Electronic Vibration Detector in stock?
Yes — 48 units are available and ready to ship from our US warehouse.
How fast will Potter EVD-1C Electronic Vibration Detector ship?
Orders placed before 3:00 PM ET ship the same business day. Delivery takes 3–5 business days inside the USA.
Where does Potter EVD-1C Electronic Vibration Detector ship from?
It ships from the United States. Standard delivery is 3–5 business days, and orders placed before 3:00 PM ET go out the same day.